Fronius Inverter Error Codes

Troubleshooting Fronius Error Codes

1 XX Fronius Inverter Error Codes
CodeMeaningWhat To Do?
#102The AC voltage is too highContact Zac Power
#103The AC voltage is too low
#105The AC frequency is too high
#106The AC frequency is too low
#107The AC grid outside the allowed limits
#108Independent operation detected
#112A residential current monitoring unit (RCMU) error has occurred
#141Grid frequency has jumped too highThis value can be adjusted to the grid via menupoint RoCoF (Rate of Change of Frequency) in the Menu. Alternatively, contact Zac Power
3 XX Fronius Inverter Error Codes
CodeMeaningWhat To Do?
#301Excess AC currentThe fault will fix itself. If the fault keeps appearing, contact Zac Power
#302Excess DC current
#303DC module overheating
#304AC module overheating
#305Power is not being fed in, although the relay is closed
#306The PV output is too low to feedThe fault will fix itself. If the fault keeps appearing even insufficient sunlight, contact Zac Power
#307The PV output is too low to feedContact Zac Power
#308The intermediate circuit voltage is too highThe fault will fix itself. If the fault keeps appearing, contact Zac Power
#309The DC input voltage MPPT (maximum power point tracker is too high)
#311The polarity of the DC strings reversed.The fault will fix itself. If the fault keeps appearing, contact Zac Power
#313The DC input voltage MPPT (maximum power point tracker) 2 is too high.
#314Current sensor calibration timeout
#315AC current sensor errorContact Zac Power
#316Interrupt check fail
#317Unbalanced intermediate circuit voltage
#318DC bank current detected
#325Connection area overheating
#326Error with fan 1
#327Error with fan 2
4 XX Fronius Inverter Error Codes
CodeMeaningWhat To Do?
#401The AC voltage is too highContact Zac Power
#406Temperature sensor for AC module is faulty (1)
#407Temperature sensor for DC module is faulty (L2)
#408DC component measured in the grind is too high
#412Fixed voltage mode has selected instead of MPP voltage mode and the fixed voltage mode has been set at the wrong value.If this code continues to appear, contact Zac Power
#415Safety cut out has triggered via option card or RECERBOContact Zac Power
#416Power stage set has no communication with control system
#417Hardware ID issueContact Zac Power
#419Unique ID issue
#420Unable to communicate with hybrid manager
#421HID ranger error
#425Unable to communicate with power stage set
#426, #427, #428Hardware fault
#431Software faultConduct an AC reset (switch it off and on); update inverter firmware, if the fault continues to appear, contact Zac Power
#436Functional incompatibilityContact Zac Power
#437Power stage fault
#438Functional incompatibility
#443The intermediate circuit voltage is too low or asymmetric
#445Compatibility fault – invalid power stage set configuration
#447Insulation problemIf the fault continues to appear, contact Zac Power
#448The neutral conductor is not connected.
#450The guard can’t be foundIf the fault continues to appear, contact Zac Power
#451Memory fault detected
#452Communication problem between processors
#453Power stage set and grid voltage are not compatible
#454Power stage and grid frequency are not compatible
#456Anti-islanding function is no longer implemented correctly
#457The grid relay sticking or the neutral conductor ground voltage is too high
#458Issues when recording measuring signal.Contact Zac Power
#459Issues when recording the measuring signal for insulation test.
#460Reference voltage source for the DSP (digital signal processor) is working out of tolerance
#461Error in the DSP (digital signal processor) data memory
#462Fault with the DC feed monitoring routine
#463Reversed AC polarity, The AC connector has been incorrect;y inserted
#474The RCMU sensor is faulty
#475Insulation fault (the connection between the solar panel and the ground is faulty)
#476The driver supply voltage is too low
#479Intermediate circuit relay has switched off
#480, #481Functional incompatibility (one or more PC boards in the inverter are not compatible together)Contact Zac Power
#482The setup phase after the initial start-up was interrupted.Conduct an AC reset (turn it off and on again); complete start-up
#483The voltage UDC fixed on MPP2 string is out of limits.Check MPP setting, if code continues to appear contact Zac Power
#485The CAN transmit buffer is fullConduct an AC reset (turn it off and on again); codes continues to appear then contact Zac Power
#489Permanent intermediate circuit capacitor overvoltage.Contact Zac Power
5 XX Fronius Inverter Error Codes
Code MeaningWhat To Do?
#502Insulation fault on the solar panelIf code continues to appear, contact Zac Power
#509No energy has been fed into the grid in the last 24 hoursCheck for any other state code, if code continues to appear, contact Zac Power
#515Unable to communicate with filterIf code continues to appear, contact Zac Power
#516Unable to communicate with storage unit
#517Overheating which is causing power deratingPurge cooling air openings, the fault will fix itself; if code continues to appear, contact Zac Power
#518Internal DSP faultIf code continues to appear, contact Zac Power
#519Unable to communicate with storage unit
#520No energy has been fed into the grid by MPPT1 in the past 24 hours
#522The DC is low on string 1
#523The DC is low in string 2
#528, #529There is a functional incompatibility (one or more of the PC boards are not compatible)Contact Zac Power
#560The grid frequency has become excessively high which is causing deratingCode will fix itself; if the code continues to appear, contact Zac Power
#564There is a functional incompatibility (one or more of the PC boards are not compatible)Contact Zac Power
#566The arc detector has been deactivatedPress enter (4th button from the left).
#567The GVDPR (grid voltage-dependent power reduction mode) is active and the inverter will operate with reduced power outputIf code continues to appear, contact Zac Power
XX 6 Fronius Inverter Error Codes
CodeMeaningWhat To Do?
#601The CAN bus is fullContact Zac Power
#603The AC module sensor is faulty
#604The DC module sensor is faulty.
#607RCMU faultPress enter (4th from the left button); if the code keeps showing, contact Zac Power
#608There is a functional incompatibility (one or more of the PC boards are not compatible)Update the inverters firmware, if the code continues to appear, contact Zac Power
#609Configuration Value of LimitsSeek intervention by a Fronius-trained service engineer.
XX 7 Fronius Inverter Error Codes
CodeMeaningWhat To Do?
#701-716Information about the internal processors statusIf code continues to appear, contact Zac Power
#721EEPROM has been reinitialized
#722-730INformation about the internal processors status
#731USB flash drive not supportedCheck the USB flash drive and the files, if necessary, replace.
#732Initialisation error with USB flash drive
#733USB flash drive not connectedCheck the USB flash drive and the files, if necessary, replace; contact Zac Power
#734Update file not recognised or missingCheck the update file for issues, if necessary change file to match the device; if the code keeps showing, contact Zac Power
#735Update file is too old or does not match the device
#736Write read errorCheck the USB flash drive and the files, if necessary, replace; If code continues to appear, contact Zac Power
#737Unable to open file
#738Unable to save log fileCreate space on the USB flash drive; Check the USB flash drive and the files, if necessary, replace; If code continues to appear, contact Zac Power
#740Error in file system on USB flash driveCheck the USB flash drive and the files, if necessary, replace; If code continues to appear, contact Zac Power
#741Error recording logging data
#743Error during updateTry the update again, check USB flash drive and replace if necessary; if the code keeps showing, contact Zac Power
#745The update file is corruptDownload update file retry update; if the code keeps appearing, contact Zac Power
#746Error while updatingWait few minutes and try updating again; if the code keeps showing, contact Zac Power
#751Time lostReset the time and date on the inverter; if the code continues to appear contact Zac Power
#752Communication error with real-time clock module
#753The real-time clock module is in emergency modeReset the time and date;if the code continues to appear contact Zac Power
#754-755Information about the processors statusIf the code continues to appear contact Zac Power
#757Real-time clock module hardware errorReal-time clock module hardware error
#758Real-time clock module is in emergency modeReal-time clock module is in emergency mode
#760Internal hardware faultIf the code continues to appear contact Zac Power
#761-765Information about the internal processors status
#766Emergency power derating has triggered
#767Information about the internal processors status
#768There is a contrasting power limitation in the hardware modules
#772Storage unit unavailable
#773Invalid country setup
#775The OMC power stage set unavailablePress enter (4th button from the left); if the code continues to appear contact Zac Power
#776The device type is invalid
#779CAN bus transmission errorContact Zac Power
#781-794Information about the internal processors statusIf this code keeps showing, contact Zac Power

Zac Power Services

Zac Power offers comprehensive electrical services in Cowra and surrounding areas, boasting over 8 years of experience, licensed electricians, and a commitment to top-notch workmanship and professionalism.

Solar Services
Solar installations, maintenance, panels, inverters, battery & off-grid.
Electrical Services
Zac Power provide top-quality electrical services in Cowra NSW.
Air Conditioning
Expert installation for split systems and ducted air conditioning units.
We focus on delivering a personalised service throughout Cowra and surrounds. Providing a trusted local service to the community and exceed customer satisfaction on every job.